151 lines
4.2 KiB
TOML
151 lines
4.2 KiB
TOML
|
|
||
|
#Wires
|
||
|
[wires]
|
||
|
#Small Connector max output in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
small_connector_max_output = 1000
|
||
|
#Small Connector max input in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
small_connector_max_input = 1000
|
||
|
#Small Connector With Light energy consumption in FE/t.
|
||
|
#Range: > 0
|
||
|
small_light_connector_consumption = 1
|
||
|
#Large Connector max wire length in blocks.
|
||
|
#Range: 0 ~ 256
|
||
|
large_connector_wire_length = 32
|
||
|
#Small Connector max wire length in blocks.
|
||
|
#Range: 0 ~ 256
|
||
|
small_connector_wire_length = 16
|
||
|
#Large Connector max input in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
large_connector_max_input = 5000
|
||
|
#Allows blocks attached to a connector to freely pass energy to and from the connector network.
|
||
|
connector_allow_passive_io = true
|
||
|
#Large Connector max output in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
large_connector_max_output = 5000
|
||
|
#Ignore checking if block face can support connector.
|
||
|
connector_ignore_face_check = true
|
||
|
|
||
|
#Make sure config changes are duplicated on both Clients and the Server when running a dedicated Server,
|
||
|
# as the config isnt synced between Clients and Server.
|
||
|
#General Settings
|
||
|
[general]
|
||
|
#Max stress for the Alternator and Electric Motor (in SU at 256 RPM).
|
||
|
#Range: > 0
|
||
|
max_stress = 16384
|
||
|
#Forge Energy conversion rate (in FE/t at 256 RPM, value is the FE/t generated and consumed is at 256rpm).
|
||
|
#Range: > 0
|
||
|
fe_at_max_rpm = 480
|
||
|
#If audio should be enabled or not.
|
||
|
audio_enabled = true
|
||
|
|
||
|
#Portable Energy Interface
|
||
|
[portable_energy_interface]
|
||
|
#PEI max output in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
pei_max_output = 5000
|
||
|
#PEI max input in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
pei_max_input = 5000
|
||
|
|
||
|
#Electric Motor
|
||
|
[electric_motor]
|
||
|
#Electric Motor internal capacity in FE.
|
||
|
#Range: > 0
|
||
|
motor_capacity = 5000
|
||
|
#Electric Motor minimum required energy consumption in FE/t.
|
||
|
#Range: > 0
|
||
|
motor_min_consumption = 8
|
||
|
#Electric Motor max input in FE (Energy transfer not consumption).
|
||
|
#Range: > 0
|
||
|
motor_max_input = 5000
|
||
|
#Electric Motor min/max RPM.
|
||
|
#Range: > 1
|
||
|
motor_rpm_range = 256
|
||
|
|
||
|
#Tesla Coil
|
||
|
[tesla_coil]
|
||
|
#Tesla Coil charge rate in FE/t.
|
||
|
#Range: > 0
|
||
|
tesla_coil_charge_rate = 5000
|
||
|
#Tesla Coil fire interval (in ticks).
|
||
|
#Range: > 0
|
||
|
tesla_coil_fire_cooldown = 20
|
||
|
#Hurt range (in blocks/meters).
|
||
|
#Range: > 0
|
||
|
tesla_coil_hurt_range = 3
|
||
|
#Tesla Coil internal capacity in FE.
|
||
|
#Range: > 0
|
||
|
tesla_coil_capacity = 40000
|
||
|
#Energy consumed when Tesla Coil is fired (in FE).
|
||
|
#Range: > 0
|
||
|
tesla_coil_hurt_energy_required = 1000
|
||
|
#The duration of the Shocked effect for mobs (in ticks).
|
||
|
#Range: > 0
|
||
|
tesla_coil_effect_time_mob = 20
|
||
|
#The duration of the Shocked effect for players (in ticks).
|
||
|
#Range: > 0
|
||
|
tesla_coil_effect_time_player = 20
|
||
|
#Tesla Coil max input in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
tesla_coil_max_input = 10000
|
||
|
#Tesla Coil charge rate in FE/t for recipes.
|
||
|
#Range: > 0
|
||
|
tesla_coil_recipe_charge_rate = 2000
|
||
|
#Damaged dealt to mobs when Tesla Coil is fired (in half hearts).
|
||
|
#Range: > 0
|
||
|
tesla_coil_hurt_mob = 3
|
||
|
#Damaged dealt to players when Tesla Coil is fired (in half hearts).
|
||
|
#Range: > 0
|
||
|
tesla_coil_hurt_player = 2
|
||
|
|
||
|
#Alternator
|
||
|
[alternator]
|
||
|
#Alternator efficiency relative to base conversion rate.
|
||
|
#Range: 0.01 ~ 1.0
|
||
|
generator_efficiency = 0.75
|
||
|
#Alternator internal capacity in FE.
|
||
|
#Range: > 0
|
||
|
generator_capacity = 5000
|
||
|
#Alternator max input in FE (Energy transfer, not generation).
|
||
|
#Range: > 0
|
||
|
generator_max_output = 5000
|
||
|
|
||
|
#Accumulator
|
||
|
[accumulator]
|
||
|
#Accumulator internal capacity per block in FE.
|
||
|
#Range: > 0
|
||
|
accumulator_capacity = 2000000
|
||
|
#Accumulator max output in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
accumulator_max_output = 5000
|
||
|
#Accumulator max input in FE/t (Energy transfer).
|
||
|
#Range: > 0
|
||
|
accumulator_max_input = 5000
|
||
|
#Accumulator max multiblock height.
|
||
|
#Range: 1 ~ 8
|
||
|
accumulator_max_height = 5
|
||
|
#Accumulator max multiblock width.
|
||
|
#Range: 1 ~ 8
|
||
|
accumulator_max_width = 3
|
||
|
|
||
|
#Rolling Mill
|
||
|
[rolling_mill]
|
||
|
#Rolling Mill duration in ticks.
|
||
|
#Range: > 0
|
||
|
rolling_mill_processing_duration = 120
|
||
|
#Rolling Mill base stress impact.
|
||
|
#Range: 0 ~ 1024
|
||
|
rolling_mill_stress = 8
|
||
|
|
||
|
#Misc
|
||
|
[misc]
|
||
|
#Diamond Grit Sandpaper durability (number of uses).
|
||
|
#Range: > 3
|
||
|
diamond_grit_sandpaper_uses = 1024
|
||
|
#Barbed Wire Damage.
|
||
|
#Range: 0.0 ~ 3.4028234663852886E38
|
||
|
barbed_wire_damage = 2.0
|
||
|
|